Chromatography Research - Column Chromatography, Gas Chromatography (GC), Liquid Chromatograpy, HPLC

Chromatography Research Today is a free monthly online journal that collates and summarizes the latest research about Chromatography, including details on column chromatography, gas chromatography (gc), liquid chromatograpy, hplc.


Chromatography Research Today

Home

View Latest Issue

Information About Chromatography

Books on Chromatography

Advertising in Research Today

View Other Research Today Publications



Multiresidue method for the analysis of more than 140 pesticide residues in fruits and vegetables by gas chromatography coupled to triple quadrupole mass spectrometry.

Fernández Moreno JL, Garrido Frenich A, Plaza Bolaños P, Martínez Vidal JL

Research Group Analytical Chemistry of Contaminants, Department of Analytical Chemistry, University of Almeria, 04071 Almeria, Spain.

A new multiresidue method has been developed and validated for the determination of more than 140 pesticide residues in cucumber and orange by gas chromatography coupled to triple quadrupole mass spectrometry (GC-QqQ-MS/MS) in a single run of 25.50 min. The triple quadrupole (QqQ) analyzer simultaneously operated in the selected reaction monitoring (SRM) and selected ion monitoring (SIM) modes, acquiring two or three transitions per compound. Samples were extracted by the application of a single-phase extraction of 10 g of sample with acetonitrile containing 1% of acetic acid, followed by a liquid-liquid partition formed by the addition of 4 g of MgSO(4) and 1 g of NaOAc. A dispersive solid-phase extraction (D-SPE) with primary secondary amine (PSA) was applied to clean up the extracts. A final concentration step was included in order to increase sensitivity in the instrumental analysis. The method was properly validated in each matrix in a wide dynamic range (10-400 microg kg(-1)): this work relies on a new quantification strategy by the use of two calibration curves to increase the dynamic range, which permitted reduction of sample dilutions and increase in sample throughput. Recovery was studied at three concentration levels (11.5, 50.0, and 150.0 microg kg(-1)), yielding values in the range 70-110% with precision values, expressed as relative standard deviation (RSD), lower than 20 and 25% for the intraday and interday precision, respectively. Limits of quantification (LOQs) were established at 10 microg kg(-1), the lowest maximum residue level (MRL) value set by the European Union in vegetables. The method was successfully applied to the analysis of pesticide residues in real samples from the southeastern Spain.

Published 2 September 2008 in J Mass Spectrom, 43(9): 1235-54.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2005-2009 Chromatography Research Today. All Rights Reserved.



Chromatography Research Today Archive:

Volume 1 (2005)
  Issue 1 (September)
  Issue 2 (October)
  Issue 3 (November)
  Issue 4 (December)

Volume 2 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 5 (2009)
  Issue 1 (January)



Chromatography Books

Columns for Gas Chromatography: Performance and Selection

Columns for Gas Chromatography: Performance and Selection