Chromatography Research - Column Chromatography, Gas Chromatography (GC), Liquid Chromatograpy, HPLC

Chromatography Research Today is a free monthly online journal that collates and summarizes the latest research about Chromatography, including details on column chromatography, gas chromatography (gc), liquid chromatograpy, hplc.


Chromatography Research Today

Home

View Latest Issue

Information About Chromatography

Books on Chromatography

Advertising in Research Today

View Other Research Today Publications



Direct determination of dialkyl phosphates by strong anion-exchange liquid chromatography/atmospheric pressure chemical ionization mass spectrometry using a quadrupole ion trap instrument.

Draper WM, Behniwal P, Wijekoon D

Sanitation and Radiation Laboratory Branch, California Department of Public Health, 850 Marina Bay Parkway, Richmond, CA 94804, USA. william.draper@cdph.ca.gov

The direct determination of dialkyl phosphates (DAPs) in water by strong anion-exchange (SAX) liquid chromatography/atmospheric pressure chemical ionization (APCI) mass spectrometry was investigated. The SAX high-performance liquid chromatography (HPLC) column was eluted with methanol/water gradients containing ammonium formate (AF) separating the DAPs which included six dimethyl- and diethyl-substituted phosphates, thiophosphates, and dithiophosphates. The high buffer concentrations required for separation were compatible with -ve APCI, but in +ve APCI the DAPs were unstable giving anomalous ions such as [M+15]+ and [M+29]+. These ions are believed to result from ion molecule reactions with CH3OH2+ in the plasma. DAPs are very stable in -ve APCI being detected as abundant [M-H](-) ions, even with 200 mM AF. At higher AF concentration formate clusters ([M+45](-) and [M+91](-)) were seen. Fragmentation by collision-activated dissociation (CAD) was more efficient for deprotonated ethyl-substituted DAPs which lost ethylene followed by ethanol. APCI instrument detection limits were in the low ng/mL range and the response was highly linear. Isotope dilution quantitation using d10-diethyl dithiophosphate (DEDTP) as an internal standard produced an instrument detection limit of 2 ng DEDTP/mL and method detection limit (MDL) of 9.3 ng/mL with accuracy of 99% (spike concentration, 25 ng/mL). DAP mixtures required storage in cold, dry conditions and alcohol solvents should be avoided because of solvolysis reactions.

Published 11 August 2008 in Rapid Commun Mass Spectrom, 22(17): 2613-20.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2005-2009 Chromatography Research Today. All Rights Reserved.



Chromatography Research Today Archive:

Volume 1 (2005)
  Issue 1 (September)
  Issue 2 (October)
  Issue 3 (November)
  Issue 4 (December)

Volume 2 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 5 (2009)
  Issue 1 (January)



Chromatography Books

Crime Lab Chemistry: A Chromatography Mystery (GEMS Teacher's Guide for Grades 4-8)

Crime Lab Chemistry: A Chromatography Mystery (GEMS Teacher's Guide for Grades 4-8)