Chromatography Research - Column Chromatography, Gas Chromatography (GC), Liquid Chromatograpy, HPLC

Chromatography Research Today is a free monthly online journal that collates and summarizes the latest research about Chromatography, including details on column chromatography, gas chromatography (gc), liquid chromatograpy, hplc.


Chromatography Research Today

Home

View Latest Issue

Information About Chromatography

Books on Chromatography

Advertising in Research Today

View Other Research Today Publications



Analysis of catecholamines and their metabolites in adrenal gland by liquid chromatography tandem mass spectrometry.

Gu Q, Shi X, Yin P, Gao P, Lu X, Xu G

National Chromatographic R. & A. Center, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, 457 Zhongshan Road, Dalian 116023, China.

Two simple, rapid and specific analytical methods for 13 catecholamines and their metabolites have been developed based on liquid chromatography tandem mass spectrometry in a multiple reaction monitoring mode. Tyrosine, dopamine, dihydroxyphenylalanine, epinephrine, norepinephrine, 3-methoxytyramine, normetanephrine, metanephrine and isoproterenol (internal standard) were separated on a Kromasil Cyano analytical column by a mobile phase consisting of 60% (v/v) acetonitrile and 40% (v/v) water adjusted with formic acid to pH 3.0, and detected by positive ionization electrospray tandem mass spectrometry. While vanillymandelic acid, 3,4-dihydroxymandelic acid, homovanillic acid, 3,4-dihydroxyphenylacetic acid, 4-hydroxy-3-methoxyphenylglycol and 5-hydroxy-2-indolecarboxylic acid (internal standard) were separated on a reversed-phase Shim-Pak VP-ODS column with the mobile phase of 60% (v/v) acetonitrile, and 40% (v/v) water adjusted with formic acid to pH 4.5 and detected in the negative ionization electrospray tandem mass spectrometry. The influence of various parameters such as column type and mobile phase composition on separation and sensitivity were investigated. The limits of detection were in the range of 0.5-20ngmL(-1). The mean recoveries determined from three different concentrations of each analyte were above 85.4%. The precision of the method calculated as relative standard deviation was lower than 5.3%. Deduced from the results of real sample analysis, adrenal gland synthesizes and stores the catecholamine hormones norepinephrine and epinephrine.

Published 11 February 2008 in Anal Chim Acta, 609(2): 192-200.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2005-2008 Chromatography Research Today. All Rights Reserved.



Chromatography Research Today Archive:

Volume 1 (2005)
  Issue 1 (September)
  Issue 2 (October)
  Issue 3 (November)
  Issue 4 (December)

Volume 2 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)



Chromatography Books

The Troubleshooting and Maintenance Guide for Gas Chromatographers

The Troubleshooting and Maintenance Guide for Gas Chromatographers