Chromatography Research - Column Chromatography, Gas Chromatography (GC), Liquid Chromatograpy, HPLC

Chromatography Research Today is a free monthly online journal that collates and summarizes the latest research about Chromatography, including details on column chromatography, gas chromatography (gc), liquid chromatograpy, hplc.


Chromatography Research Today

Home

View Latest Issue

Information About Chromatography

Books on Chromatography

Advertising in Research Today

View Other Research Today Publications



Pharmacokinetic study of puerarin in rat serum by liquid chromatography tandem mass spectrometry.

Prasain JK, Peng N, Acosta E, Moore R, Arabshahi A, Meezan E, Barnes S, Wyss JM

Department of Pharmacology and Toxicology, University of Alabama at Birmingham, Birmingham, AL 35294, USA. jprasain@uab.edu

A highly sensitive and specific atmospheric pressure chemical ionization liquid chromatography-tandem mass spectrometry method was developed for serum pharmacokinetic studies of puerarin in rats. Chromatography was carried out on a reversed-phase Phenomenex Synergi 4 microm Fusion-RP80 column (150 x 2.0 mm i.d.) using a mobile phase consisting of acetonitrile-water (10:90, v/v) in 10 mm NH(4)OAc with a flow rate of 0.2 mL/min. Puerarin was analyzed in the multiple reaction monitoring mode with a precursor/product ion transition of m/z 415/267. The method was demonstrated to be specific and sensitive, and a linear response was observed over a range of 2-5000 ng/mL in rat serum. The validated method was successfully applied to the characterization of the pharmacokinetics of puerarin in rat serum after oral administration to spontaneously hypertensive rats. The blood concentration-time profile of puerarin showed a rapid initial increase, reaching a maximum and then declining within 1 h. Puerarin could not be detected after 24 h. The main pharmacokinetic parameters for puerarin after oral administration were as follows: C(max) (3.54 +/- 2.03 mg/L), T(max) (0.68 +/- 0.37 h), AUC(0-t) (7.29 +/- 3.79 mg h/L), AUC(0-infinity) (9.17 +/- 4.87 mg h/L), T(1/2) (1.7 +/- 0.6 h), CL/F (7.24 +/- 4.27 L/h/kg) and V/F (17.88 +/- 13.55 L/h/kg).

Published 2 April 2007 in Biomed Chromatogr, 21(4): 410-4.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2005-2008 Chromatography Research Today. All Rights Reserved.



Chromatography Research Today Archive:

Volume 1 (2005)
  Issue 1 (September)
  Issue 2 (October)
  Issue 3 (November)
  Issue 4 (December)

Volume 2 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)



Chromatography Books

Troubleshooting HPLC Systems: A Bench Manual

Troubleshooting HPLC Systems: A Bench Manual