Chromatography Research - Column Chromatography, Gas Chromatography (GC), Liquid Chromatograpy, HPLC

Chromatography Research Today is a free monthly online journal that collates and summarizes the latest research about Chromatography, including details on column chromatography, gas chromatography (gc), liquid chromatograpy, hplc.


Chromatography Research Today

Home

View Latest Issue

Information About Chromatography

Books on Chromatography

Advertising in Research Today

View Other Research Today Publications



Stacking and separation of fluorescent derivatives of amino acids by micellar electrokinetic chromatography in the presence of poly(ethylene oxide).

Chiu TC, Chang HT

Department of Chemistry, National Taiwan University, Taipei, Taiwan.

A new approach for the analysis of large-volume naphthalene-2,3-dicarboxaldehyde (NDA) derivatives of amino acids by micellar electrokinetic chromatography (MEKC) in conjunction with a purple light-emitting diode-induced fluorescence detection is described. In order to optimize resolution, speed, and stacking efficiency, a discontinuous condition is essential for the analysis of NDA-amino acid derivatives. The optimum conditions use 2.0M TB (pH 10.0) buffer containing 40mM sodium dodecyl sulfate (SDS) to fill the capillary, deionized water to dilute samples, and 200mM TB (pH 9.0) containing 10mM SDS to prepare 0.6% poly(ethylene oxide) (PEO). Once high voltage is applied, PEO solution enters the capillary via electroosmotic flow and SDS micelles interact and thus sweep the NDA-amino acid derivatives having smaller electrophoretic mobilities than that of SDS micelles in the sample zone. When the aggregates between SDS micelles and NDA amino acid derivatives enter PEO zone, they are stacked due to decrease in electric field and increases in viscosity. Under the optimum conditions, the concentration and separation of 0.53-microL 13 NDA-amino acid derivatives that are negatively charged has been demonstrated by using a 60-cm capillary, with the efficiencies 0.3-9.0x10(5) theoretical plates and the LODs at signal-to-noise ratio 3 ranging from 0.30 to 2.76nM. When compared to standard injection (30-cm height for 10s), the approach allows the sensitivity enhancements over the range of 50-800 folds for the derivatives. The new approach has been applied to the analysis of a red wine sample, with great linearity of fluorescent intensity against concentrations (R(2)>0.98) and the RSD (three repetitive runs in one day) values of the migration times for the ten identified amino acids less than 2.8%.

Published 12 March 2007 in J Chromatogr A, 1146(1): 118-24.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2005-2008 Chromatography Research Today. All Rights Reserved.



Chromatography Research Today Archive:

Volume 1 (2005)
  Issue 1 (September)
  Issue 2 (October)
  Issue 3 (November)
  Issue 4 (December)

Volume 2 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)



Chromatography Books

Preparative Chromatography Techniques: Applications in Natural Product Isolation

Preparative Chromatography Techniques: Applications in Natural Product Isolation