Chromatography Research - Column Chromatography, Gas Chromatography (GC), Liquid Chromatograpy, HPLC

Chromatography Research Today is a free monthly online journal that collates and summarizes the latest research about Chromatography, including details on column chromatography, gas chromatography (gc), liquid chromatograpy, hplc.


Chromatography Research Today

Home

View Latest Issue

Information About Chromatography

Books on Chromatography

Advertising in Research Today

View Other Research Today Publications



Generation of improved gas linear velocities in a comprehensive two-dimensional gas chromatography system.

Tranchida PQ, Casilli A, Dugo P, Dugo G, Mondello L

Dipartimento Farmaco-Chimico, Facoltà di Farmacia, Università di Messina, viale Annunziata, 98168-Messina, Italy.

A comprehensive two-dimensional gas chromatography (GC x GC) system (for convenience defined as "split flow" GC x GC), which may be operated at improved gas linear velocities in both dimensions, has been developed. The setup is formed of an apolar 30 m x 0.25 mm i.d. column connected, by means of a Y press fit, to a detector-linked 1 m x 0.1 mm i.d. polar analytical column, which passes through the (cryogenic) modulator, and to a 0.3 m x 0.1 mm i.d. retention gap, which is connected to a manually operated split valve. The latter enables the regulation of gas flows through the second analytical column [e.g., 60:40 (FID) ratio, 50:50 ratio, 40:60 (FID) ratio, etc.], in order to generate the most appropriate gas linear velocity, which is related to each specific analysis. In the pre-sent investigation, two sets of traditional and split flow GC x GC analyses were carried out on a cod liver oil fatty acid methyl ester sample by using the same temperature programs [180-250 degrees C at (a) 3 degrees C/min and at (b) 1.3 degrees C/min] and at an average first-dimension linear velocity of approximately 35.0 cm/s; thus, primary column retention times (and therefore elution temperatures) were essentially maintained. The second-dimension linear velocity was calculated to be approximately 333 cm/s in the traditional applications, while it was split valve-regulated until the most appropriate values [(a) approximately 213 cm/s; (b) approximately 264 cm/s] were attained in the alternative applications. Substantial improvements were observed and measured in the chromatography along the y-axis, while the contour plot chemical class structure was maintained.

Published 14 March 2007 in Anal Chem, 79(6): 2266-75.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2005-2008 Chromatography Research Today. All Rights Reserved.



Chromatography Research Today Archive:

Volume 1 (2005)
  Issue 1 (September)
  Issue 2 (October)
  Issue 3 (November)
  Issue 4 (December)

Volume 2 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)



Chromatography Books

HPLC Made to Measure: A Practical Handbook for Optimization

HPLC Made to Measure: A Practical Handbook for Optimization