Chromatography Research - Column Chromatography, Gas Chromatography (GC), Liquid Chromatograpy, HPLC

Chromatography Research Today is a free monthly online journal that collates and summarizes the latest research about Chromatography, including details on column chromatography, gas chromatography (gc), liquid chromatograpy, hplc.


Chromatography Research Today

Home

View Latest Issue

Information About Chromatography

Books on Chromatography

Advertising in Research Today

View Other Research Today Publications



Quantification of phosphatidylserine, phosphatidic acid and free fatty acids in an ultrasound contrast agent by normal-phase high-performance liquid chromatography with evaporative light scattering detection.

Hvattum E, Uran S, Sandbaek AG, Karlsson AA, Skotland T

GE Healthcare Medical Diagnostics, Nycoveien 2, N-0401 Oslo, Norway.

Sonazoid is a new contrast agent for ultrasound imaging. The product is an aqueous suspension of perfluorobutane microbubbles coated with phospholipids obtained from hydrogenated egg phosphatidylserine (H-EPS). A normal-phase high-performance liquid chromatographic (HPLC) method with evaporative light scattering detection was developed for quantification of free fatty acids, phosphatidylserine and phosphatidic acid in H-EPS and Sonazoid. Separation of the lipids was carried out on an HPLC diol column and a gradient of chloroform and methanol with 0.2% formic acid titrated to pH 7.5 with ammonia. The calibration standards contained stearic acid, distearoyl-phosphatidic acid (DSPA) and distearoyl-phosphatidylserine (DSPS) in the concentration range of 0.016-1.0mg/ml (0.4-25microg injected). The method was validated with a limit of quantification of the three lipids set to 0.4microg (approximately 20-60microM). The best fit of the three calibration curves were obtained when the logarithmic transformed theoretical lipid concentration was plotted against the logarithmic transformed area under the peak and fitted to a second order polynomial equation. Stearic acid, DSPA and DSPS were analysed with an intermediate precision ranging from 4.4% to 5.3% R.S.D. and they were extracted from an aqueous suspension with a recovery ranging from 103.3% to 113.3%. The sum of total phospholipid concentration determined in H-EPS ranged from 96.4% to 103.2% of the theoretical values. The lipids in the ultrasound product were quantitated with a repeatability ranging from 6.2% to 11.7% R.S.D.

Published 20 September 2006 in J Pharm Biomed Anal, 42(4): 506-12.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2005-2008 Chromatography Research Today. All Rights Reserved.



Chromatography Research Today Archive:

Volume 1 (2005)
  Issue 1 (September)
  Issue 2 (October)
  Issue 3 (November)
  Issue 4 (December)

Volume 2 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)



Chromatography Books

HPLC Made to Measure: A Practical Handbook for Optimization

HPLC Made to Measure: A Practical Handbook for Optimization