Chromatography Research - Column Chromatography, Gas Chromatography (GC), Liquid Chromatograpy, HPLC

Chromatography Research Today is a free monthly online journal that collates and summarizes the latest research about Chromatography, including details on column chromatography, gas chromatography (gc), liquid chromatograpy, hplc.


Chromatography Research Today

Home

View Latest Issue

Information About Chromatography

Books on Chromatography

Advertising in Research Today

View Other Research Today Publications



Quantitative determination of erythrocyte folate vitamer distribution by liquid chromatography-tandem mass spectrometry.

Smith DE, Kok RM, Teerlink T, Jakobs C, Smulders YM

Department of Clinical Chemistry, ICaR-VU, VU University Medical Center, Amsterdam, The Netherlands.

BACKGROUND: Given the role of folate in many disorders, intracellular distribution of folate vitamers is of potential clinical importance. In particular, accumulation of non-methyltetrahydrofolates due to altered partitioning of folate metabolism at the level of methylenetetrahydrofolate is of interest. METHODS: We describe a positive-electrospray liquid chromatography tandem mass spectrometry (LC-MS/MS) method that allows determination of erythrocyte folate vitamer distribution by accurately measuring both 5-methyltetrahydrofolate (5-methylTHF) and non-methyl folate vitamers. Whole blood lysates are deconjugated in ascorbic acid solutions, deproteinized, purified using folate-binding protein affinity columns, concentrated by solid-phase extraction (SPE) and evaporation, and separated on a C18 column within 6 min. RESULTS: The limit of quantification for both 5-methylTHF and non-methylTHF was 0.4 nmol/L (signal-to-noise >10). Intra- and inter-assay CVs for 5-methylTHF were 1.2% and 2.8%, respectively. Intra- and inter-assay CVs for non-methylTHF as a group were 1.6% and 1.5%, respectively. Recovery results were 97-107%. We measured 8-72% non-methyl folate vitamers in volunteers (n=5) with the methylenetetrahydrofolate reductase (MTHFR) 677 TT genotype. Concentrations ranged from 117 to 327 nmol/L and 23 to 363 nmol/L for 5-methylTHF and non-methylTHF vitamers, respectively. We measured 0-2% non-methylTHF vitamers in MTHFR 677 CC genotype volunteers. In addition, we found that storage of whole-blood samples in ascorbic acid at low pH resulted in 53-90% loss of the non-methylTHF fraction. CONCLUSION: This LC-MS/MS method accurately determines erythrocyte 5-methylTHF and non-methyl folate vitamers.

Published 7 April 2006 in Clin Chem Lab Med, 44(4): 450-9.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2005-2008 Chromatography Research Today. All Rights Reserved.



Chromatography Research Today Archive:

Volume 1 (2005)
  Issue 1 (September)
  Issue 2 (October)
  Issue 3 (November)
  Issue 4 (December)

Volume 2 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)



Chromatography Books

The Troubleshooting and Maintenance Guide for Gas Chromatographers

The Troubleshooting and Maintenance Guide for Gas Chromatographers