Chromatography Research - Column Chromatography, Gas Chromatography (GC), Liquid Chromatograpy, HPLC

Chromatography Research Today is a free monthly online journal that collates and summarizes the latest research about Chromatography, including details on column chromatography, gas chromatography (gc), liquid chromatograpy, hplc.


Chromatography Research Today

Home

View Latest Issue

Information About Chromatography

Books on Chromatography

Advertising in Research Today

View Other Research Today Publications



Determination of cyanide in blood by isotope-dilution gas chromatography-mass spectrometry.

Murphy KE, Schantz MM, Butler TA, Benner BA, Wood LJ, Turk GC

National Institute of Standards and Technology, Gaithersburg, MD 20899, USA. karen.murphy@nist.gov

BACKGROUND: Cyanide (CN) is a lethal toxin. Quantification in blood is necessary to indicate exposure from many sources, including food, combustion byproducts, and terrorist activity. We describe an automated procedure based on isotope-dilution gas chromatography-mass spectrometry (ID GC/MS) for the accurate and rapid determination of CN in whole blood. METHODS: A known amount of isotopically labeled potassium cyanide (K13C15N) was added to 0.5 g of whole blood in a headspace vial. Hydrogen cyanide was generated through the addition of phosphoric acid, and after a 5-min incubation, 0.5 mL of the headspace was injected into the GC/MS at an oven temperature of -15 degrees C. The peak areas from the sample, 1H12C14N+, at m/z 27, and the internal standard, 1H13C15N+, at m/z 29, were measured, and the CN concentration was quantified by ID. The analysis time was 15 min for a single injection. RESULTS: We demonstrated method accuracy by measuring the CN content of unfrozen whole blood samples fortified with a known amount of CN. Intermediate precision was demonstrated by periodic analyses over a 14-month span. Relative expanded uncertainties based on a 95% level of confidence with a coverage factor of 2 at CN concentrations of 0.06, 0.6, and 1.5 microg/g were 8.3%, 5.4%, and 5.3%, respectively. The mean deviation from the known value for all concentrations was <4%. CONCLUSION: The automated ID GC/MS method can accurately and rapidly quantify nanogram per gram to microgram per gram concentrations of CN in blood.

Published 2 March 2006 in Clin Chem, 52(3): 458-67.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2005-2008 Chromatography Research Today. All Rights Reserved.



Chromatography Research Today Archive:

Volume 1 (2005)
  Issue 1 (September)
  Issue 2 (October)
  Issue 3 (November)
  Issue 4 (December)

Volume 2 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)



Chromatography Books

Liquid Chromatography-Mass Spectrometry, Third Edition (Chromatographic Science)

Liquid Chromatography-Mass Spectrometry, Third Edition (Chromatographic Science)