Chromatography Research - Column Chromatography, Gas Chromatography (GC), Liquid Chromatograpy, HPLC

Chromatography Research Today is a free monthly online journal that collates and summarizes the latest research about Chromatography, including details on column chromatography, gas chromatography (gc), liquid chromatograpy, hplc.


Chromatography Research Today

Home

View Latest Issue

Information About Chromatography

Books on Chromatography

Advertising in Research Today

View Other Research Today Publications



Sensitive and convenient method for the quantification of clonidine in serum of pediatric patients using liquid chromatography/tandem mass spectrometry.

Müller C, Ramic M, Harlfinger S, Hünseler C, Theisohn M, Roth B

University of Cologne, Department of Pharmacology, Medical Faculty of the University of Cologne, Gleuelerstrasse 24, 50931 Köln, Germany. c.mueller@uni-koeln.de

An improved and easy to use liquid chromatography/tandem mass spectrometric (LC/MS/MS) method in human serum was developed for the quantification of clonidine (CLD), an alpha2-/alpha1-adrenoceptor agonist, used for analgo-sedation and the therapy of opioid withdrawal in pediatric patients. Sample preparation consisted of precipitation of serum proteins by adding acetonitrile and centrifugation of the sample subsequently. [(2)H4]Clonidine (CLD4) served as internal standard. Chromatographic separation of the supernatant was achieved using a 100mmx3mm, 5microm Thermo Electron BetaBasic C4 column with isocratic flow and elution consisting of 0.1% formic acid/acetonitrile (85/15, v/v) and a flow-rate of 350microl/min resulting in a column pressure of 280-420kPa. LC/MS/MS detection was performed by using a triple-stage quadrupole mass spectrometer (TSQ Quantum, Thermo Electron) working in selected reaction monitoring mode with positive electrospray ionization. The analyte was quantified in a single run within 5min. Linearity was demonstrated over the expected concentration range 0.15-50microg/l CLD. The lower limit of quantification (LLOQ) and the limit of detection were 0.1microg/l and 0.01microg/l, respectively. None of the drugs used concomitantly during analgesic therapy interfered in the assay in vitro. Intra-day precision expressed as RSD was 9.6% or less for CLD, while inter-day result was 10.0% or less for CLD. Intra-day and inter-day accuracy was within +/-4.9% and +/-1.8%, respectively. The method was validated according to the international guidelines of the International Conference on Harmonisation (ICH) and the US Food and Drugs Administration (FDA). The described method is suitable to analyse serum samples with very small volumes and sets the stage for pharmacokinetic studies in pediatric studies.

Published 25 December 2006 in J Chromatogr A, 1139(2): 221-7.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2005-2008 Chromatography Research Today. All Rights Reserved.



Chromatography Research Today Archive:

Volume 1 (2005)
  Issue 1 (September)
  Issue 2 (October)
  Issue 3 (November)
  Issue 4 (December)

Volume 2 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)



Chromatography Books

Plant Drug Analysis: A Thin Layer Chromatography Atlas

Plant Drug Analysis: A Thin Layer Chromatography Atlas