Chromatography Research - Column Chromatography, Gas Chromatography (GC), Liquid Chromatograpy, HPLC

Chromatography Research Today is a free monthly online journal that collates and summarizes the latest research about Chromatography, including details on column chromatography, gas chromatography (gc), liquid chromatograpy, hplc.


Chromatography Research Today

Home

View Latest Issue

Information About Chromatography

Books on Chromatography

Advertising in Research Today

View Other Research Today Publications



Determination of ofloxacin, norfloxacin, and ciprofloxacin in sewage by selective solid-phase extraction, liquid chromatography with fluorescence detection, and liquid chromatography--tandem mass spectrometry.

Lee HB, Peart TE, Svoboda ML

Aquatic Ecosystem Protection Research Division, Water Science and Technology Directorate, Science and Technology Branch, Environment Canada, 867 Lakeshore Road, Burlington, Ontario L7R 4A6, Canada. bill.lee@ec.gc.ca

A solid-phase extraction (SPE) and liquid chromatographic (LC) method was developed for the determination of selected fluoroquinolone (FQ) drugs including ofloxacin, norfloxacin, and ciprofloxacin in municipal wastewater samples. Extraction of the FQs was carried out with a weak cation exchanger SPE cartridge, the Oasis WCX. The cartridge was washed with water and methanol as a cleanup before the FQs were eluted by a mixture of methanol, acetonitrile, and formic acid. Separation of the FQs was achieved by using a Zorbax SB-C8 column under isocratic condition at a flow rate of 0.2mL/min. Recoveries of the FQs in spiked final effluent samples were between 87 and 94% with a relative standard deviation of less than 6%. Several techniques have been evaluated for the detection of FQs in sewage extracts; they included fluorescence detection and electrospray ionization (ESI) mass spectrometry using either mass-selective detection or tandem mass spectrometry (MS/MS). When they were applied to sewage influent and effluent samples, the LC-MS/MS technique operating in the multiple reaction monitoring (MRM) mode proved to be best suited for the determination of FQs in sewage samples as it provided the highest sensitivity (limit of quantification 5ng/L) and selectivity. The observation of signal suppression (matrix effect) for some FQs in ESI LC-MS and LC-MS/MS is discussed and a solution is proposed. The three FQs were detected in all the sewage samples tested in this work, with median concentrations between 34 and 251ng/L.

Published 25 December 2006 in J Chromatogr A, 1139(1): 45-52.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2005-2009 Chromatography Research Today. All Rights Reserved.



Chromatography Research Today Archive:

Volume 1 (2005)
  Issue 1 (September)
  Issue 2 (October)
  Issue 3 (November)
  Issue 4 (December)

Volume 2 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 5 (2009)
  Issue 1 (January)



Chromatography Books

Chapters In The Evolution Of Chromatography

Chapters In The Evolution Of Chromatography