Chromatography Research - Column Chromatography, Gas Chromatography (GC), Liquid Chromatograpy, HPLC

Chromatography Research Today is a free monthly online journal that collates and summarizes the latest research about Chromatography, including details on column chromatography, gas chromatography (gc), liquid chromatograpy, hplc.


Chromatography Research Today

Home

View Latest Issue

Information About Chromatography

Books on Chromatography

Advertising in Research Today

View Other Research Today Publications



Orthogonal test design for optimization of supercritical fluid extraction of daphnoretin, 7-methoxy-daphnoretin and 1,5-diphenyl-1-pentanone from Stellera chamaejasme L. and subsequent isolation by high-speed counter-current chromatography.

Peng J, Dong F, Xu Q, Xu Y, Qi Y, Han X, Xu L, Fan G, Liu K

School of Pharmacy, Dalian Medical University, No. 465 Zhongshan Road, Dalian 116027, China. jinyongpeng2005@163.com

Supercritical fluid extraction (SFE) of daphnoretin, 7-methoxy-daphnoretin and 1,5-diphenyl-1- pentanone from Stellera chamaejasme L. was performed. An orthogonal L9 (3)4 test design was applied to select the optimum extraction parameters including pressure, temperature, modifier and sample particle size on yield using an analytical-scale SFE system. The process was then scaled up by 100 times using a preparative SFE system under the optimized conditions of 25 MPa of pressure, 45 degrees C of temperature, 40-60 mesh of sample particle size and modified CO2 with 20% methanol. The yield of the crude extract from preparative SFE was 2.65%, which contained daphnoretin 25.2%, 7-methoxy-daphnoretin 22.8% and 1,5-diphenyl-1-pentanone 21.1%, respectively. Then the crude extract was successfully isolated and separated by preparative high-speed counter-current chromatography (HSCCC) with a two-phase solvent system composed of n-hexane-ethyl acetate-methanol-water (10:13:13:10, v/v) by increasing the flow-rate of the mobile phase stepwise from 1.0 to 2.0 ml/min after 90 min. The target compounds isolated and purified by HSCCC were analyzed by high-performance liquid chromatography (HPLC). The separation produced total of 69.2mg of daphnoretin at 99.2% purity, 63.4 mg of 7-methoxy-daphnoretin at 98.7% purity and 58.3 mg of 1,5-diphenyl-1-pentanone at 98.1% purity from 300 mg of the crude extract in one-step separation. The recoveries of daphnoretin, 7-methoxy-daphnoretin and 1,5-diphenyl-1-pentanone were 90.8, 91.5 and 90.4%, respectively, in HSCCC isolation step and the chemical structure identification was carried out by MS, 1H NMR and 13C NMR.

Published 13 November 2006 in J Chromatogr A, 1135(2): 151-7.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2005-2009 Chromatography Research Today. All Rights Reserved.



Chromatography Research Today Archive:

Volume 1 (2005)
  Issue 1 (September)
  Issue 2 (October)
  Issue 3 (November)
  Issue 4 (December)

Volume 2 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 5 (2009)
  Issue 1 (January)



Chromatography Books

Chapters In The Evolution Of Chromatography

Chapters In The Evolution Of Chromatography