Chromatography Research - Column Chromatography, Gas Chromatography (GC), Liquid Chromatograpy, HPLC

Chromatography Research Today is a free monthly online journal that collates and summarizes the latest research about Chromatography, including details on column chromatography, gas chromatography (gc), liquid chromatograpy, hplc.


Chromatography Research Today

Home

View Latest Issue

Information About Chromatography

Books on Chromatography

Advertising in Research Today

View Other Research Today Publications



Qualitative and quantitative determination of ten major saponins in Platycodi Radix by high performance liquid chromatography with evaporative light scattering detection and mass spectrometry.

Ha YW, Na YC, Seo JJ, Kim SN, Linhardt RJ, Kim YS

Natural Products Research Institute, College of Pharmacy, Seoul National University, 28 Yeonkun-Dong, Jongno-Ku, Seoul 110-460, South Korea.

Saponins in Platycodi Radix (platycosides) exhibit potent biological activities in mammalian systems, including several beneficial effects such as anti-inflammatory, immunomodulatory and anti-obesity activities. In this study, we developed a new HPLC separation coupled with evaporative light scattering detector (ELSD) for the simultaneous quantitative determination of ten major saponins in Platycodi Radix. Simultaneous separation of these saponins was achieved on a C18 analytical column. The mobile phase consisted of a gradient of aqueous acetonitrile. The method was validated for linearity, precision, accuracy, limit of detection and quantification. Electrospray ionization mass spectrometry (ESI-MS) and liquid chromatography coupled with on-line mass spectrometry (LC-ESI MS/MS) were applied to identify platycosides in the purified fractions and in the crude extract. Under ESI-MS/MS conditions, the fragmentation patterns of [M-H]- ions exclusively show signals corresponding to cleavage of the glycosidic bonds, thus allowing a rapid identification of saponins in the crude extract of Platycodi Radix. The validated HPLC method provides a new basis of overall assessment on quality of Platycodi Radix, and ESI-MS/MS and LC-ESI MS/MS approaches offers analytical tools for a rapid screening of platycosides in the crude extract.

Published 1 November 2006 in J Chromatogr A, 1135(1): 27-35.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2005-2008 Chromatography Research Today. All Rights Reserved.



Chromatography Research Today Archive:

Volume 1 (2005)
  Issue 1 (September)
  Issue 2 (October)
  Issue 3 (November)
  Issue 4 (December)

Volume 2 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)



Chromatography Books

Applications of LC-MS in Toxicology

Applications of LC-MS in Toxicology