Analysis of the recent antipsychotic aripiprazole in human plasma by capillary electrophoresis and high-performance liquid chromatography with diode array detection.

Musenga A, Saracino MA, Spinelli D, Rizzato E, Boncompagni G, Kenndler E, Raggi MA

Department of Pharmaceutical Sciences, University of Bologna, Via Belmeloro 6, 40126 Bologna, Italy.

Two methods, based on the use of capillary electrophoresis (CE) and high-performance liquid chromatography (HPLC), respectively, were developed for the analysis of the atypical antipsychotic aripiprazole in plasma of schizophrenic patients for therapeutic drug monitoring purposes. Good analytical performances were obtained with the CE method, using uncoated fused silica capillaries and a background electrolyte composed of 50mM phosphate buffer at pH 2.5. With 20 kV voltage, aripiprazole was detectable at 214 nm within 5 min. The second analytical method, based on HPLC with diode array detection, employed a C8 reversed-phase column and a mixture of a 12.5mM phosphate buffer, pH 3.5, containing triethylamine and acetonitrile as the mobile phase. Aripiprazole was detected at 254 nm and a complete chromatographic run lasted about 10 min. For both analytical methods loxapine was used as the internal standard and the same plasma sample pre-treatment by means of solid-phase extraction on cyano cartridges was carried out, with extraction yield values always higher than 91.3%. Linear responses for aripiprazole were obtained between 70 and 700 ng mL(-1) and precision assays (expressed as relative standard deviation values) were lower than 7.0%. After validation, both methods were successfully applied to human plasma samples drawn from schizophrenic patients undergoing therapy with Abilify tablets. Accuracy was satisfactory, with recovery value higher than 91.0%.

Published 24 March 2008 in Anal Chim Acta, 612(2): 204-11.
Full-text of this article is available online (may require subscription).


Articles on Chromatography published 24 March 2008:

Quantitative structure-property relationship study for estimation of quantitative calibration factors of some organic compounds in gas chromatography.   Anal Chim Acta, 612(2): 126-35.

Quantitative structure-property relationship (QSPR) models have been used to predict and explain gas chromatographic data of quantitative calibration factors (f(M)). This method allows for the prediction of quantitative calibration factors in a variety of organic compounds based on their structures alone. Stepwise multiple linear regression (MLR) and non-linear radial basis function neural network (RBFNN) were performed to build the models. The statistical characteristics provided by multiple ... [Abstract] [Full-text]


Articles on Chromatography published 17 March 2008:

Characterizing and compensating for matrix effects using atmospheric pressure chemical ionization liquid chromatography-tandem mass spectrometry: analysis of neutral pharmaceuticals in municipal wastewater.   Anal Chem, 80(6): 2010-7.

Matrix effects are a great challenge for the quantitative analysis of environmental samples by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Signal suppression or enhancement can compromise the accuracy of analytical results. While matrix effects have been relatively well studied for applications of LC-MS/MS instrumentation with electrospray ionization, there have been relatively few studies to evaluate matrix effects when using atmospheric pressure chemical ionization (APCI) as ... [Abstract] [Full-text]

Development of a strategy of influenza virus separation based on pseudoaffinity chromatography on short monolithic columns.   Anal Chem, 80(6): 2188-98.

This research is devoted to the development and optimization of fine purification processes realized on short monolithic columns (CIM disks), using influenza vaccine and viruslike synthetic particles as model objects. The pseudoaffinity mode of liquid chromatography has been used as a tool for dynamic adsorption experiments. Viruslike particles, close to the dimensions of influenza viruses, were developed by means of main antigen of influenza viruses (hemeagglutinin) covalent binding to the ... [Abstract] [Full-text]


Articles on Chromatography published 14 March 2008:

Open-tubular capillary cell affinity chromatography: single and tandem blood cell separation.   Anal Chem, 80(6): 2118-24.

In this paper, an open-tubular capillary cell affinity chromatography (OT-CAC) method to enrich and separate target cells is described. Open tubular capillaries coated with anti-CD4, anti-CD14, or anti-CD19 antibodies were used as affinity chromatography columns to separate target blood cells. Cells were eluted using either shear force or bubbles. Bubbles were used to elute the captured cells without diluting the captured cells appreciably, while maintaining viability (the viability of the ... [Abstract] [Full-text]

Tailoring noise frequency spectrum between two consecutive second derivative filtering procedures to improve liquid chromatography-mass spectrometry determinations.   Anal Chem, 80(6): 2097-104.

This paper reports a simple chemometric technique to alter the noise spectrum of a liquid chromatography-mass spectrometry (LC-MS) chromatogram between two consecutive second-derivative filter procedures to improve the peak signal-to-noise (S/N) ratio enhancement. This technique is to multiply one second-derivative filtered LC-MS chromatogram with another artificial chromatogram added with thermal noises prior to the other second-derivative filter. Because the second-derivative filter cannot ... [Abstract] [Full-text]


Articles on Chromatography published 4 March 2008:

Paper-PEG-based membranes for hydrophobic interaction chromatography: purification of monoclonal antibody.   Biotechnol Bioeng, 99(6): 1434-42.

This article discusses the preparation of novel Paper-PEG interpenetrating polymer network-based membranes as inexpensive alternative to currently available adsorptive membranes. The Paper-PEG membranes were developed for carrying out hydrophobic interaction membrane chromatography (HIMC). PEG is normally very hydrophilic but can undergo phase separation and become hydrophobic in the presence of high antichaotropic salt concentrations. Two variants of the Paper-PEG membranes, Paper-PEG 1 and ... [Abstract] [Full-text]


Articles on Chromatography published 26 February 2008:

Development and validation of a liquid chromatography-mass spectrometry assay for hair analysis of methylphenidate.   Forensic Sci Int, 176(1): 42-6.

Methylphenidate (MPH) is a phenethylamine derivative used in the treatment of childhood attention-deficit hyperactivity disorder. MPH is biotransformed in the body by the hydrolysis of the methyl ester linkage to its metabolite, ritalinic acid. Whereas both compounds are usually measured in plasma and urine, preliminary observations show that only the parent compound is present in hair from treated individuals. Since in children hair samples can be easily collected without the need for special ... [Abstract] [Full-text]


Articles on Chromatography published 13 February 2008:

Comprehensive two-dimensional gas chromatography-mass spectrometry: a review.   Mass Spectrom Rev, 27(2): 101-24.

Although comprehensive two-dimensional gas chromatography (GC x GC) has been on the scene for more than 15 years, it is still generally considered a relatively novel technique and is yet far from being fully established. The revolutionary aspect of GC x GC, with respect to classical multidimensional chromatography, is that the entire sample is subjected to two distinct analytical separations. The resulting enhanced separating capacity makes this approach a prime choice when GC analysts are ... [Abstract] [Full-text]


© 2005-2008 Chromatography Research Today. All Rights Reserved.



Chromatography Research Today Archive:

Volume 1 (2005)
  Issue 1 (September)
  Issue 2 (October)
  Issue 3 (November)
  Issue 4 (December)

Volume 2 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)



Chromatography Books

HPLC of Peptides and Proteins: Methods and Protocols (Methods in Molecular Biology) (Methods in Molecular Biology)

HPLC of Peptides and Proteins: Methods and Protocols (Methods in Molecular Biology) (Methods in Molecular Biology)